Both probe models contain all of the necessary electronics internally, allowing them
to be used without a separate controller. By combining circuit board electronics
with photo detector sensing abilities, this probe can perform control or output
functions. Signal processing takes place inside the probe, and an output change
indicates and alarms when the probe tip is wet.
Point Level Sensor, Leak Detector, Pump Protector Interfaces With Computer/PLC Self Contained Stand-alone Sensor Surface Mount Electronics For Corrosives and High Purity Liquids
Description
Part Number
5 VDC
GLL100240
12-32 VDC
GLL100250
GLL100240/5VDC, 20 mA maximum - sinking (output low when wet)